Korean Journal of Otorhinolaryngology-Head and Neck Surgery > Volume 69(11); 2026 > Article
Korean Journal of Otorhinolaryngology-Head and Neck Surgery 2026;69(11): 533-541.
doi: https://doi.org/10.3342/kjorl-hns.2026.00661
Differentiation of Diplophonia Using Vibration Simulator
Jin Choon Lee1 , Soo-Geun Wang1 , In-Ho Bae2,3 , Jaewon Kim3 , Eui-Suk Sung1 , Minhyung Lee 3 , Sung-Chan Shin1 , Yong-Il Cheon4 , Ha-Nee Kwon4 , Soon-Bok Kwon2,5 , Jung Hoon Ro6
1Department of Otorhinolaryngology-Head and Neck Surgery, School of Medicine, Pusan National University, Yangsan, Korea
2Interdisciplinary Program for Cognitive Science, Pusan National University, Busan, Korea
3Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Yangsan Hospital, Yangsan, Korea
4Department of Otorhinolaryngology-Head and Neck Surgery, Pusan National University Hospital, Busan, Korea
5Department of Humanities, Language and Information, Pusan National University, Busan, Korea
6Department of Biomedical Engineering, School of Medicine, Pusan National University, Yangsan, Korea
진동 시뮬레이터를 이용한 이중음성의 감별
이진춘1 , 왕수건1 , 배인호2,3 , 김재원3 , 성의숙1 , 이민형 3 , 신성찬1 , 천용일4 , 권하늬4 , 권순복2,5 , 노정훈6
1부산대학교 의과대학 이비인후과학교실
2부산대학교 인지과학전공
3양산부산대학교병원 이비인후과
4부산대학교병원 이비인후과
5부산대학교 언어정보학과
6부산대학교 의과대학 의공학교실
Correspondence  Jung Hoon Ro ,Tel: +82-51-240-7933, Email: jhro@pnu.edu
Received: 22 August 2026; Revised: August 25, 2026   Accepted: 27 August 2026.  Published online: 20 November 2026.
ABSTRACT
Background and Objectives
This study evaluated the efficacy of a silicon vibration simulator (VS) by determining whether it could convert the acoustic energy of voice into vibration. We also compared the accuracy of digital kymography (DKG), two-dimensional digital kymography (2D DKG), acoustic voice analysis, and auditory perception for differentiating diplophonia and examined the differences between DKG and 2D DKG in this task.
Subjects and Method
One normophonic male and one vocally healthy male who can produce diplophonia participated for the verification of efficacy of a silicon VS. Twenty-nine diplophonic voice samples and 41 non-periodic voice samples were enrolled in this study. Auditory and visual perceptual judgement about DKG, 2D DKG, and the sound waveform were performed. DKG and 2D DKG images of the VS were captured by a high-speed digital camera in the multi-functional examination system.
Results
The simulator achieved exact conversion of voice-derived acoustic energy into vibration. Compared with acoustic voice analysis and auditory perceptual judgement, DKG using the VS showed the highest diagnostic validity for differentiating diplophonia as follows: 0.9655 for sensitivity; 0.9756 for specificity; 0.9714 for accuracy; the positive likelihood ratio of 39.5862 and the negative likelihood ratio of 0.0353. For 26 of the 29 diplophonic samples, differentiation was easier with 2D DKG than with DKG.
Conclusion
The silicon VS reproduced vibration patterns resembling those of human vocal folds and effectively differentiated diplophonia. Although 2D DKG generally provided more intuitive visualization, the conventional DKG was more useful for diplophonic voices containing long metacycle components.
Keywords: Digital kymographyㆍ Diplophoniaㆍ Silicon vibration simulatorㆍ 2D DKG
Editorial Office
Korean Society of Otorhinolaryngology-Head and Neck Surgery
103-307 67 Seobinggo-ro, Yongsan-gu, Seoul 04385, Korea
TEL: +82-2-3487-9091    FAX: +82-2-3487-6603   E-mail: kjorl@korl.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Society of Otorhinolaryngology-Head and Neck Surgery.                 Developed in M2PI
Close layer
prev next